Featured
- Get link
- X
- Other Apps
Condensate Drain To Sink Tailpiece
Condensate Drain To Sink Tailpiece. In stock and ready to ship. I could always have it tie in with the drain inside the wall, but i'm.

The developed length from the fixture outlet to the receptor shall not exceed 5 feet (1524 mm). Do i have to replace the existing drain that came with my. You can also connect to a wye tailpiece connected above a trap, usually under a sink.
This Fitting Is One (Or Similiar To) I’ve Used/Recommend For Condensate And Softener.
Terminating the condensate piping from an a/c system to the house drain piping under a sink is definitley allowed, but rarely done here in florida. So when you are measuring the drain size firstly measure the top part width where the drain stainer lip sits and also measure the inside of your drain hole which will be narrower. According to the imc, 3/4″ is sufficient for up to 20 tons unless the drain outlet size is larger than 3/4″.
If The Tailpiece Is Leaking, Then Water Is Falling Inside Your Kitchen Or Bathroom Cabinet.
3/4 condensate drain diameter is sufficient for up to 20 tons unless the drain outlet size on the unit itself is larger than 3/4″. But, if you choose this option, remember there are a few important things to do. Use of rubber type hose to make the connection from the pvc condensation drain to the sanitary side of the sink tailpiece is.
One Way To Get More Options About Connection Location Is To Use A Condensate Pump, Which Can Pump Through At Least 30 Feet Of Tubing If Necessary, And Probably 10 To 15 Feet Of Head If Necessary.
Free shipping on orders over $25 shipped by amazon. 1 1/4 1 1/2 length. Running the condensate line into a tail piece of a sink is actually one of the best options to drain condensate from.
White Plastic Flanged Strainer Sink.
1 1/4 1 1/2 od. 4 5 6 8 8 3/4 12 tailpiece od. The most important one relates to the position of the connections.
Where The Sink In A Bar, Soda Fountain, Or Counter Is So Located That The Trap Serving The Sink Cannot Be Vented, The Sink Drain Shall Discharge Through An Air Gap Or Air Break (See Section 801.3.3) Into An Approved Receptor That Is Vented.
What i noticed is that there is not much room for the condensate to enter the drain as there is a (gray) pipe above it that extends past the condensate tap. Do i have to replace the existing drain that came with my. The actual condensate drain has it's own inline trap to prevent the fan from sucking air from the attic.